Sign In | Join Free | My udpf.com |
|
Place of Origin : Wuhan Hubei China
Brand Name : Huaying
Certification : ISO
Model Number : Huaying Series
MOQ : 1 Set
Price : negotiable
Packaging Details : Wooden Case
Delivery Time : 7 Working Days
Payment Terms : T/T L/C
Supply Ability : 200 sets per month
Warranty : 1 year free and lifelong maintenance
Duty cycle : Customized
Power : 220V or customized
Customize service : Provided
Capacity : 5-150KVA
Current : 500-5000A
Current load Primary Current Injection Test Set 1000A 220V Single Mode
1. Product Name:
Primary Current Injection Test System SLQ
2. Equipment Description:
SLQ primary injection test set is a high current generator instrument. It is applied in current transformer test , circuit breaker test and so on. Adjustable output current, smooth in current rise, large scope of load variation, easy and safe operation.
3.Technical Parameters:
Type |
Capacity (kva) |
Power supply |
Output |
Impedance voltage % |
Idle current % |
mode |
||
I (A) |
V (V) |
I (A) |
V (V) |
|||||
SLQ-5/500 |
3 |
13.6 |
220 |
500 |
5 |
>8 |
>6 |
single |
SLQ -5/1000 |
5 |
22.7 |
220 |
1000 |
5 |
>8 |
>6 |
single |
SLQ -10/2000 |
10 |
46 |
220 |
2000 |
5 |
>8 |
>6 |
Separated |
SLQ -12/4000 |
12 |
30 |
400 |
2000/4000 |
6/3 |
>8 |
>6 |
Separated |
SLQ -15/5000 |
15 |
37.5 |
400 |
2500/5000 |
6/3 |
>8 |
>6 |
Separated |
SLQ -150/25kA |
150 |
375 |
400 |
25000 |
6 |
>8 |
>6 |
Separated |
Environment temperature: 0~50°C
Humidity: ≤85%RH
4. Safety Warnings
1) The test set must be connected to earth reliably before use
2) The output terminals should be clean before switching on
3) The test set should be in power off before make connections for the test
4) After the high current output the metal terminals are very hot. It is forbid to touch those parts
5) It is forbid to touch the terminals or high current circuit when test set is switched to ON position
6) The duty cycle should not be exceeded
7) Any replacement should be made when test set is switched off
8) The test set should never be connected to the live power line
5. The SLQ primary injection tester has two kinds of model. One is integral box and another is the separated box. The model is depends on the maximum capacity output of the whole tester. If the
whole capacity of the tester is less or equal to 5KVA, the control unit and the current booster will
be designed in one single box. Otherwise the control unit will be a one box and the current booster will be a one box.
![]() |
Current load Primary Current Injection Test Set 1000A 220V Single Mode Images |